NCT07012993

Ultralow Dose PET Imaging of 18F-Florbetapir, 18F-Flutemetamol

Akiva Mintz · Phase 2 · RECRUITING

Enrollment
200
Study start
May 20, 2025
Primary completion
Jun 30, 2030
ESTIMATED

Registered primary endpoints

Signal-to-Noise Ratio (SNR)

Measurement of signal-to-noise ratio for image quality assessment across different scan durations, reconstruction techniques, and artificial intelligence (AI)-enhanced image reconstructions. Unit of Measure: SNR (unitless, numeric ratio)

Time frame: Evaluated annually (once per year), based on pooled images acquired during the preceding 12-month period.

Contrast-to-Noise Ratio (CNR)

Measurement of contrast-to-noise ratio for image quality assessment across different scan durations, reconstruction techniques, and AI-enhanced image reconstructions. Unit of Measure: CNR (unitless, numeric ratio)

Time frame: Evaluated annually (once per year), based on pooled images acquired during the preceding 12-month period.

Coefficient of Variation (COV)

Measurement of the coefficient of variation in selected regions for evaluating image consistency across different scan durations, reconstruction techniques, and AI-enhanced image reconstructions. Unit of Measure: Percentage (%)

Time frame: Evaluated annually (once per year), based on pooled images acquired during the preceding 12-month period.

Spatial Resolution (Full Width at Half Maximum - FWHM)

Assessment of spatial resolution using full width at half maximum (FWHM) across different scan durations, reconstruction techniques, and AI-enhanced image reconstructions. Unit of Measure: Millimeters (mm)

Time frame: Evaluated annually (once per year), based on pooled images acquired during the preceding 12-month period.

Target-to-Background Ratio (TBR)

Assessment of target-to-background ratio for evaluating PSMA-expressing tissue contrast across different scan durations, reconstruction techniques, and AI-enhanced image reconstructions. Unit of Measure: Ratio (unitless numeric ratio)

Time frame: Evaluated annually (once per year), based on pooled images acquired during the preceding 12-month period.

Qualitative Image Quality Score (Likert Scale)

Independent qualitative evaluation of overall image quality, lesion detectability, image noise, and artifacts by nuclear medicine physicians, assessed using a 5-point Likert scale. Unit of Measure: Score on Likert Scale (1-5; 1 = worst, 5 = best)

Time frame: Evaluated annually (once per year), based on pooled images acquired during the preceding 12-month period.

Inter-reader Agreement (Weighted Kappa Statistics)

Measurement of agreement among readers evaluating qualitative image quality scores, analyzed using weighted kappa statistics. Unit of Measure: Weighted kappa statistic (numeric value ranging from 0 to 1, 0 = no agreement, 1 = perfect agreement)

Time frame: Evaluated annually (once per year), based on pooled images acquired during the preceding 12-month period.

Linked assets

Original registry record

ClinicalTrials.gov · NCT07012993

Registry last update: Apr 13, 2026 · Retrieved Nov 24, 2026

Estimated completion dates are not confirmed results disclosure dates.